DEVELOPMENT AND VALIDATION OF A STABILITY INDICATING RP HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF VALSARTAN AND SACUBITRIL IN TABLET DOSAGE FORM

Authors

  • D. Reshma Bhanu Pharmaceutics Dr.K.V. Subba Reddy Institute of Pharmacy (Approved by AICTE,P.C.l New Delhi& Permanently Affiliated to JNTUA Anantapuramu MOU with Government General Hospital &KMC, K urnool . Author
  • M. G. Maddilety Pharmaceutics Dr.K.V. Subba Reddy Institute of Pharmacy (Approved by AICTE,P.C.l New Delhi& Permanently Affiliated to JNTUA Anantapuramu MOU with Government General Hospital &KMC, K urnool. Author
  • S. Neelofar Sulthana Pharmaceutics Dr.K.V. Subba Reddy Institute of Pharmacy (Approved by AICTE,P.C.l New Delhi& Permanently Affiliated to JNTUA Anantapuramu MOU with Government General Hospital &KMC, K urnool. Author

DOI:

https://doi.org/10.62649/

Keywords:

Sacubitril, Valsartan, RP‐HPLC, Validation.

Abstract

Objective: A New method was established for simultaneous estimation of Sacubitril And Valsartan by RP-HPLC method. Methods: Chromatographic separations were carried using Spurcil C18 (4.6 x 250mm, 5m) (Dikma column) column with a mobile phase composition of 0.1% OPA buffer and Acetonitrile(50:50) have been delivered at a flow rate of 1ml/min and the detection was carried out using waters HPLC auto sampler, separation module 2695 with PDA detector at wavelength 237 nm. Results: The retention time for Sacubitril and Valsartan were 3.119 and 6.851 minute respectively. The correlation coefficient values in linearity were found to be 0.999 and concentration range 12-60 μg/ml for Sacubitril and 13- 65µg/ml for Valsartan respectively. For accuracy the total recovery was found to be 99.98% and 100.28% for Sacubitril and Valsartan. The LOD and LOQ concentration for Sacubitril were found to be 0.02 µg/ml and 0.05 µg/ml and LOD and LOQ for Valsartan were found to be 0.01µg/ml and 0.04 µg/ml. The force degradation studies were performed and the results are within the limits. Conclusion: The results of study showed that the proposed RP‐HPLC method is a simple, accurate, precise, rugged, robust, fast and reproducible, which may be useful for the routine estimation of Sacubitril and Valsartan in pharmaceutical dosage form.